Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by HFA  
Thermal performance U 0,16 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 47 dB
Ln,w (Cl)
Assessed by TU-GRAZ  
Mass per unit area m 96,0 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awmohi02a-03 (pdf, 250 KB)

Note

Attention: REI 90 (from inside) in Germany possible with 2x12,5mm GKF/GF


Cross laminated timber: Var. 04-06: at least 3-layers, top layer at least 30mm; var. 03: d ≥ 85mm; at least 5-layers, top layer at least 17mm

Only for registered members after logging in.
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C vapour-permeable membrane sd ≤ 0,3m
D 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
E 200,0 construction timber (60/200; e=625) 0,120 50 450 1,600 D
F 200,0 mineral wool [040; 11; <1000°C; r>5] 0,040 1 11 1,030 A2
G 90,0 cross laminated timber 0,130 50 500 1,600 D
H 70,0 battens (60/60) on resilient clips, e=660 0,120 50 450 1,600
I 50,0 mineral wool [040; 13; <1000°C] 0,040 1 13 1,030 A2
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 65,9 kg
Share of renewable materials of total weight 70,11 %
Global warming potential (GWP-T) -68,578 kgCO2Äqv.
Energy use of Primary Energy 751,7 MJ
Share of renewable Primary Energy 16,7 %
∑ΔOI3 34,5
Calculated with gypsum plaster board type DF; this data includes 3-, 5-, and 7-ply cross laminated timber elements;  
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 36,736 -105,314 -68,578 125,854 1022,675 1148,530 625,884 21,007 646,891 0,182 0,081 3.4814116E-6 0,050

Last update 02.08.2023/nu.ge