Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35 kN/m  
Classified by HFA  
Fire performance Germany
Classification: REI 60 (from inside/from outside); Attention: REI 90 (from inside) possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,15 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 53 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 102,6 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awmohi02a-04 (pdf, 250 KB)

Note

Attention: REI 90 (from inside) in Germany possible with 2x12,5mm GKF/GF


Cross laminated timber: Var. 04-06: at least 3-layers, top layer at least 30mm; var. 03: d ≥ 85mm; at least 5-layers, top layer at least 17mm

Only for registered members after logging in.
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C vapour-permeable membrane sd ≤ 0,3m
D 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
E 200,0 construction timber (60/200; e=625) 0,120 50 450 1,600 D
F 200,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
G 100,0 cross laminated timber 0,130 50 500 1,600 D
H 70,0 battens (60/60) on resilient clips, e=660 0,120 50 450 1,600
I 50,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 72,9 kg
Share of renewable materials of total weight 72,24 %
Global warming potential (GWP-T) -76,951 kgCO2Äqv.
Energy use of Primary Energy 796,8 MJ
Share of renewable Primary Energy 16,2 %
∑ΔOI3 36,2
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 39,327 -116,278 -76,951 129,258 1125,275 1254,533 667,532 23,584 691,116 0,195 0,086 3.695161E-6 0,055

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 72,5 kg
Biogenic carbon 104,9 kgCO2Äqv.
Energy use of Primary Energy 874,3 MJ
Share of renewable Primary Energy 36,0 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -86,562 0,151 0,026 3.29E-6 0,022 312,729 1248,389 1558,982 524,886 47,167 571,600
C1 - C4 120,299 0,004 0,003 2.25E-7 0,001 0,871 -1236,777 -1235,906 21,858 -0,100 21,760
A1 - C4 37,064 0,159 0,030 3.53E-6 0,023 314,466 12,131 324,460 559,870 47,184 606,600

Last update 02.08.2023/nu.ge