Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by MA39/HFA  
Fire performance Germany
Classification: REI60 (from inside/from outside); Attention: REI 90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,20 W/(m2K)
Diffusion adequate
Calculated by HFA  
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 50 dB (-3; -9)
Ln,w (Cl)
Rw=48dB if a lightweight ETICS insulation Panel (ρ approx. 90kg/m³) is applied.  
Assessed by Müller-BBM  
Mass per unit area m 94,3 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

Datenblatt external wall
awmopi01a-00 (pdf, 250 KB)

Note

Attention: REI90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board

solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 120,0 mineral wool MW-PT [041; 155] ETICS insulation panel 0,041 1 155 1,030 A1
C 100,0 cross laminated timber 0,130 50 500 1,600 D
D 70,0 spruce wood battens (60/60) mounted on resilient clips; e=660 0,120 50 450 1,600 D
E 50,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon 28,5
Calculated by HFA  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-30,1 0,306 872,4 1.091,8 0,047 0,074

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 51,8 kg
Biogenic carbon 74,7 kgCO2 Äqv.
Energy use of Primary Energy 825,1 MJ
Share of renewable PE 29,3 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -45,325 0,208 0,033 3,2E-6 0,021 240,575 887,681 1.126,046 559,473 34,111 593,040
C1 - C4 86,698 0,005 0,006 1,52E-7 0,001 0,768 -879,492 -878,561 17,634 0,000 19,840
A1 - C4 44,313 0,216 0,039 3,36E-6 0,021 241,729 8,447 248,334 583,324 34,163 622,520

Last update 28.08.2018/hfa.plb