Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
90
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by HFA  
Fire performance Germany
Classification: REI60 (from inside/from outside); Attention: REI 90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,21 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 50 dB (-3; -9)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 94,7 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awmopi01a-10 (pdf, 250 KB)

Note

Attention: REI90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board

Only for registered members after logging in.
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 120,0 wood-fibre insulation board [0,045; R=160] ETICS insulation panel 0,045 5-7 160 2,100 E
C 100,0 cross laminated timber 0,130 50 500 1,600 D
D 70,0 spruce wood battens (60/60) mounted on resilient clips; e=660 0,120 50 450 1,600 D
E 50,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 62,6 kg
Share of renewable materials of total weight 72,11 %
Global warming potential (GWP-T) -58,782 kgCO2Äqv.
Energy use of Primary Energy 720,9 MJ
Share of renewable Primary Energy 8,9 %
∑ΔOI3 38,5
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 40,536 -99,317 -58,782 63,891 947,654 1011,545 657,005 38,164 695,169 0,189 0,081 3.6225746E-6 0,047

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 79,4 kg
Biogenic carbon 114,2 kgCO2Äqv.
Energy use of Primary Energy 936,1 MJ
Share of renewable Primary Energy 38,6 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -82,979 0,118 0,024 2.68E-6 0,022 359,263 1188,191 1545,244 547,553 32,654 579,660
C1 - C4 113,892 0,003 0,001 1.49E-7 0,000 1,311 -1182,747 -1181,271 22,049 -21,224 3,030
A1 - C4 32,521 0,124 0,026 2.84E-6 0,022 360,956 5,703 364,817 575,125 11,482 591,640

Last update 02.08.2023/nu.ge