Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
90
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by HFA  
Fire performance Germany
Classification: REI60 (from inside/from outside); Attention: REI 90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,16 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -9)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 104,3 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awmopi01a-12 (pdf, 250 KB)

Note

Attention: REI90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board

Only for registered members after logging in.
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 180,0 wood-fibre insulation board [0,045; R=160] ETICS insulation panel 0,045 5-7 160 2,100 E
C 100,0 cross laminated timber 0,130 50 500 1,600 D
D 70,0 spruce wood battens (60/60) mounted on resilient clips; e=660 0,120 50 450 1,600 D
E 50,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 68,9 kg
Share of renewable materials of total weight 73,73 %
Global warming potential (GWP-T) -63,672 kgCO2Äqv.
Energy use of Primary Energy 820,4 MJ
Share of renewable Primary Energy 9,3 %
∑ΔOI3 44,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 46,337 -110,009 -63,672 76,095 1055,897 1131,991 744,258 48,388 792,647 0,211 0,092 4.066552E-6 0,050

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 93,2 kg
Biogenic carbon 134,0 kgCO2Äqv.
Energy use of Primary Energy 1110,9 MJ
Share of renewable Primary Energy 38,9 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -93,349 0,137 0,028 2.73E-6 0,026 430,414 1339,818 1768,022 646,272 43,266 688,990
C1 - C4 128,274 0,003 0,001 1.5E-7 0,000 1,690 -1334,374 -1332,519 26,587 -31,836 -3,040
A1 - C4 36,533 0,143 0,030 2.89E-6 0,026 432,486 5,703 436,347 678,382 11,482 694,900

Last update 02.08.2023/nu.ge