Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
90
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by HFA  
Fire performance Germany
Classification: REI60 (from inside/from outside); Attention: REI 90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by HFA  
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 50 dB (-3; -9)
Ln,w (Cl)
Rw=48dB if a lightweight ETICS insulation panel (ρ approx. 90kg/m³) is applied.  
Rating by Müller-BBM  
Mass per unit area m 97,4 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awmopi01a-02 (pdf, 250 KB)

Note

Attention: REI90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board

Only for registered members after logging in.
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 140,0 mineral wool MW-PT [041; 155] ETICS insulation panel 0,041 1 155 1,030 A1
C 100,0 cross laminated timber 0,130 50 500 1,600 D
D 70,0 spruce wood battens (60/60) mounted on resilient clips; e=660 0,120 50 450 1,600 D
E 50,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 50,0 kg
Share of renewable materials of total weight 52,83 %
Global warming potential (GWP-T) -12,113 kgCO2Äqv.
Energy use of Primary Energy 993,2 MJ
Share of renewable Primary Energy 5,7 %
∑ΔOI3 82,3
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 65,821 -77,934 -12,113 56,248 731,169 787,417 936,905 17,714 954,619 0,394 0,127 4.2422827E-6 0,147

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 51,8 kg
Biogenic carbon 74,7 kgCO2Äqv.
Energy use of Primary Energy 864,8 MJ
Share of renewable Primary Energy 28,4 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -42,506 0,229 0,036 3.3E-6 0,022 244,511 888,138 1130,439 594,367 37,891 631,720
C1 - C4 86,960 0,005 0,007 1.53E-7 0,001 0,803 -879,492 -878,525 18,411 0,000 20,620
A1 - C4 47,615 0,237 0,043 3.46E-6 0,023 245,701 8,905 252,764 619,109 37,943 662,090

Last update 02.08.2023/nu.ge