Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by MA39/HFA  
Fire performance Germany
Classification: REI60 (from inside/from outside); Attention: REI 90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,15 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -9)
Ln,w (Cl)
Rw=49dB if a lightweight ETICS insulation panel (ρ approx. 90kg/m³) is applied.  
Assessed by Müller-BBM  
Mass per unit area m 103,4 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

Datenblatt external wall
awmopi01a-09 (pdf, 250 KB)

Note

Attention: REI90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board

solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 180,0 mineral wool MW-PT [040; 155] ETICS insulation panel 0,040 1 155 1,030 A1
C 100,0 cross laminated timber 0,130 50 500 1,600 D
D 70,0 spruce wood battens (60/60) mounted on resilient clips; e=660 0,120 50 450 1,600 D
E 50,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 51,8 kg
Biogenic carbon 74,4 kgCO2 Äqv.
Energy use of Primary Energy 944,3 MJ
Share of renewable PE 26,9 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -36,868 0,271 0,041 3,5E-6 0,024 252,382 889,053 1.139,225 664,153 45,452 709,060
C1 - C4 87,483 0,006 0,008 1,55E-7 0,001 0,875 -879,492 -878,453 19,965 0,000 22,170
A1 - C4 54,221 0,280 0,050 3,66E-6 0,025 253,645 9,820 261,623 690,680 45,504 741,220

Last update 28.08.2018/hfa.plb