Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
90
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by HFA  
Thermal performance U 0,35 W/(m2K)
Diffusion adequate
Calculated by HFA  
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 49 dB (-3; -8)
Ln,w (Cl)
Assessed by TU-GRAZ  
Mass per unit area m 106,0 kg/m2
 

data sheet external wall
awmopo01a-03 (pdf, 250 KB)

Note

Cross laminated timber:
Variation 00-03: d ≥ 78,0; at least 3-layers, top layer at least 25 mm; variation 04-07: at least 3-layers, top layer at least 30 mm

Only for registered members after logging in.
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 15,0 plaster 1,000 10-35 2000 1,130 A1
B 100,0 multilayer wood wool composite claddingboard (WW-MW-WW) 0,047 2-3 200 1,000 B
C 80,0 solid glued wood (e.g. cross laminated timber) 0,130 50 500 1,600 D
D 12,5 gypsum plaster board type DF / gypsum fibre board 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 40,7 kg
Share of renewable materials of total weight 44,18 %
Global warming potential (GWP-T) -8,747 kgCO2Äqv.
Energy use of Primary Energy 784,4 MJ
Share of renewable Primary Energy 5,1 %
∑ΔOI3 62,2
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 51,475 -60,223 -8,747 40,010 561,164 601,174 744,432 14,544 758,976 0,288 0,098 3.6608823E-6 0,097