Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
30
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35 kN/m  
Classified by HFA  
Fire performance Germany
Classification: REI 30 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,21 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 43 dB (-1; -6)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 81,1 kg/m2
 
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [046; 200] 0,046 3-7 200 2,100 E
C 120,0 construction timber (60/...; e=625) 0,120 50 450 1,600 D
D 120,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
E 90,0 cross laminated timber 0,130 50 500 1,600 D
F without gypsum board lining

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 63,0 kg
Share of renewable materials of total weight 81,76 %
Global warming potential (GWP-T) -63,282 kgCO2Äqv.
Energy use of Primary Energy 678,3 MJ
Share of renewable Primary Energy 10,8 %
∑ΔOI3 34,6
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 37,833 -101,115 -63,282 73,196 976,017 1049,214 605,128 41,130 646,258 0,177 0,076 3.2557542E-6 0,044

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 69,5 kg
Biogenic carbon 100,0 kgCO2Äqv.
Energy use of Primary Energy 985,3 MJ
Share of renewable Primary Energy 40,7 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -91,567 0,113 0,024 2.56E-6 0,024 399,332 1269,904 1667,897 562,084 37,316 598,950
C1 - C4 121,288 0,002 0,000 1.23E-7 0,000 1,543 -1269,880 -1268,173 22,291 -29,859 -5,360
A1 - C4 30,400 0,117 0,025 2.69E-6 0,023 400,875 0,024 399,928 584,375 7,457 596,960

Last update 02.08.2023/nu.ge