Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside)/F30 (from outside)  
Load Ed,fi according to the German certification document
Proof: F60 (from inside): manufacturer-specific; F30 (from outside): DIN 4102-4:2016-05  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -10)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 61,2 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D 200,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 200,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
F 15,0 OSB 0,130 200 600 1,700 D
G 40,0 spruce wood cross battens (a=400) ≥ 40mm 0,120 50 450 1,600 D
H 40,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 32,2
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -44,426 0,186 0,053 1,73e-6 0,033 87,078 745,246 832,324 416,171 30,633 446,805

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 46,7 kg
Biogenic carbon 67,8 kgCO2 Äqv.
Energy use of Primary Energy 662,0 MJ
Share of renewable PE 30,6 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -49,284 0,127 0,022 1,80e-6 0,026 201,394 792,808 994,209 440,426 33,732 474,250
C1 - C4 76,259 0,003 0,003 1,06e-7 0,000 0,845 -787,179 -786,335 12,416 -21,420 -9,000
A1 - C4 29,912 0,132 0,025 1,91e-6 0,026 202,628 5,888 208,521 459,409 12,364 471,860

Last update 07.05.2020/hfa.plb