Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, ventilated, with dry lining, with cladding
Fire performance |
REI
from inside
REI from outside |
60
30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by MA39 Classified by HFA
|
||
Thermal performance | U | 0,16 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 52 dB (-3; -10) |
Ln,w (Cl) | ||
Battens for the ventilation space screwed onto the structural timber together with vertical battens for the dry lining screwed directly onto the ledger beams will result in Rw(C;Ctr)=45(-1;-5)
Assessed by MA39 |
||
Mass per unit area | m | 46,8 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 24,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 30,0 | spruce wood battens offset (30/50; 30/80) - ventilation | 0,120 | 50 | 450 | 1,600 | D |
C | 15,0 | fibreboard (MDF) | 0,140 | 11 | 600 | 1,700 | D |
D | 240,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | 240,0 | mineral wool [040; ≥16; <1000°C] | 0,040 | 1 | 16 | 1,030 | A1 |
F | 15,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
G | 40,0 | spruce wood cross battens (a=400) resp. battens offset | 0,120 | 50 | 450 | 1,600 | D |
H | 40,0 | mineral wool [040; ≥16; <1000°C] | 0,040 | 1 | 16 | 1,030 | A1 |
I | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
I | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 26,660 | -73,859 | -47,198 | 136,304 | 768,336 | 904,640 | 473,077 | 28,891 | 501,968 | 0,146 | 0,065 | 2.4272472E-6 | 0,028 |
Last update 02.08.2023/hfa.eco2soft