Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m  
Classified by HFA  
Thermal performance U 0,26 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-1; -7)
Ln,w (Cl)
Battens for the ventilation space screwed onto the structural timber together with vertical battens for the dry lining screwed directly onto the ledger beams will result in Rw(C;Ctr)=44(-1;-5) dB  
Rating by MA39  
Mass per unit area m 55,4 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 20,0 gypsum fibre board (2x10 mm) 0,320 21 1000 1,100 A2
E 120,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
F 120,0 construction timber (60..; e=*) 0,120 50 450 1,600 D
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H 40,0 spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I 40,0 mineral wool [040; ≥16; <1000°C] or air layer in type 02 0,040 1 16 1,030 A1
J 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
J 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 32,0 kg
Share of renewable materials of total weight 49,99 %
Global warming potential (GWP-T) -30,654 kgCO2Äqv.
Energy use of Primary Energy 507,3 MJ
Share of renewable Primary Energy 19,3 %
∑ΔOI3 24,2
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 23,424 -54,078 -30,654 98,010 536,362 634,372 409,308 19,335 428,642 0,113 0,050 2.4065206E-6 0,007

Last update 02.08.2023/hfa.eco2soft