external wall timber frame construction, ventilated, with dry lining, with cladding
Fire performance | REI from inside REI from outside |
30 30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by HFA
Fire performance Germany
Classification: F30 (from inside/from outside)
Load Ed,fi according to the German certification document
Proof: manufacturer-specific
|
||
Thermal performance | U | 0,18 W/(m2K) |
Diffusion | adequate | |
Calculated by TUM
|
||
Acoustic performance | Rw (C;Ctr) | 59 dB (-1; -6) |
Ln,w (Cl) | ||
Rating by Müller-BBM
|
||
Mass per unit area | m | 67,8 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 24,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 30,0 | spruce wood battens offset (30/50; 30/80) - ventilation | 0,120 | 50 | 450 | 1,600 | D |
C | wind barrier | 1000 | |||||
D | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
E | 200,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
F | 200,0 | Cellulose fibre [040; 50] | 0,040 | 1 | 50 | 2,000 | E |
G | vapour barrier sd≥ 5m | 1000 | |||||
H | 12,5 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
I | 40,0 | spruce wood cross battens (a=400) ≥ 40mm | 0,120 | 50 | 450 | 1,600 | D |
J | 40,0 | Cellulose fibre [040; 50] ≥40mm | 0,040 | 1 | 50 | 2,000 | E |
K | 12,5 | gypsum plaster board type A | 0,250 | 4-10 | 680 | 1,050 | A2 |
ΔOI3 | 19,6 |
---|---|
Calculated by HFA
|
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kg CO2 Äqv.] |
AP [kg SO2 Äqv.] |
EP [kg PO4 Äqv.] |
ODP [kg R11 Äqv.] |
POCP [kg Ethen Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -39,921 | 0,108 | 0,046 | 2,08e-6 | 0,006 | 82,086 | 565,217 | 647,303 | 345,551 | 10,862 | 356,413 |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kg CO2 Äqv.] |
AP [kg SO2 Äqv.] |
EP [kg PO4 Äqv.] |
ODP [kg R11 Äqv.] |
POCP [kg Ethen Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -53,350 | 0,057 | 0,011 | 6,08e-7 | 0,009 | 138,232 | 666,679 | 804,668 | 206,849 | 37,146 | 244,090 |
C1 - C4 | 67,011 | 0,008 | 0,009 | 1,55e-7 | 0,001 | 0,448 | -459,777 | -459,330 | 18,392 | -0,100 | 18,290 |
A1 - C4 | 14,747 | 0,069 | 0,021 | 7,85e-7 | 0,010 | 139,817 | 207,679 | 347,253 | 240,929 | 37,202 | 278,220 |
Last update 07.05.2020/hfa.plb