Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, ventilated, without dry lining, with cladding
Fire performance | REI from inside REI from outside |
60 30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by MA39 Classified by HFA
|
||
Thermal performance | U | 0,28 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 47 dB (-2; -8) |
Ln,w (Cl) | ||
Battens for the ventilation space screwed onto the structural timber result in an Rw(C;Ctr)=43(-1;-7) dB
Assessed by MA39 |
||
Mass per unit area | m | 42,9 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 24,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 30,0 | spruce wood battens offset (30/50; 30/80) - ventilation | 0,120 | 50 | 450 | 1,600 | D |
C | 15,0 | fibreboard (MDF) | 0,140 | 11 | 600 | 1,700 | D |
D | 160,0 | construction timber (60/..; e=400) | 0,120 | 50 | 450 | 1,600 | D |
E | 160,0 | mineral wool [040; ≥16; <1000°C] | 0,040 | 1 | 16 | 1,030 | A1 |
F | 15,0 | OSB (sealed with airtight tape) | 0,130 | 200 | 600 | 1,700 | D |
G | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
G | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
∑ΔOI3 | 20,3 |
---|---|
Calculated by HFA |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase | GWP [kgCO2Äqv.] | AP [kgSO2Äqv.] | EP [kgPO4Äqv.] | ODP [kgR11Äqv.] | POCP [kgEthenÄqv.] | PERE [MJ] | PERM [MJ] | PERT [MJ] | PENRE [MJ] | PENRM [MJ] | PENRT [MJ] |
A1 - A3 | -48,574 | 0,113 | 0,050 | 1,86e-6 | 0,023 | 125,954 | 727,064 | 853,018 | 372,910 | 28,891 | 401,802 |
Last update 02.08.2023/hfa.eco2soft