Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,14 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 48 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 62,2 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awrhho07a-13 (pdf, 250 KB)

Note

According to OIB-RL 2 (Austria) is for ventilated and insulated facades (from building class 2) an insulation material with minimum Euroclass D required.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens - ventilation 0,120 50 450 1,600 D
C 30,0 spruce wood cross battens 0,120 50 450 1,600 D
D wind barrier 1000
E 60,0 wood-fibre insulation board [045; 140] 0,045 2-5 140 2,100 E
F 240,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
G 240,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
H 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 42,2 kg
Share of renewable materials of total weight 70,90 %
Global warming potential (GWP-T) -38,626 kgCO2Äqv.
Energy use of Primary Energy 588,0 MJ
Share of renewable Primary Energy 22,1 %
∑ΔOI3 32,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 31,111 -69,737 -38,626 130,222 719,643 849,864 457,746 29,328 487,074 0,167 0,061 2.1325643E-6 0,055

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 48,1 kg
Biogenic carbon 70,6 kgCO2Äqv.
Energy use of Primary Energy 687,4 MJ
Share of renewable Primary Energy 33,1 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -46,572 0,126 0,021 9.69E-7 0,024 225,731 750,784 976,573 438,547 55,156 493,810
C1 - C4 72,079 0,003 0,003 8.53E-8 0,000 1,134 -744,378 -743,245 15,090 -17,052 -1,960
A1 - C4 28,277 0,131 0,024 1.06E-6 0,024 227,253 6,664 233,975 460,118 38,156 498,380

Last update 02.08.2023/hfa.eco2soft