Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by MA39  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 47 dB (-2; -8)
Ln,w (Cl)
Assessed by MA39  
Mass per unit area m 39,9 kg/m2
Calculation based on gypsum plaster board type DF GF
 

data sheet external wall
awrhho07a-02 (pdf, 250 KB)

Note

According to OIB-RL 2 (Austria) is for ventilated and insulated facades (from building class 2) an insulation material with minimum Euroclass D required.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens - ventilation 0,120 50 450 1,600 D
C 30,0 spruce wood cross battens 0,120 50 450 1,600 D
D wind barrier 1000
E 60,0 wood-fibre insulation board [045; 140] 0,045 2-5 140 2,100 E
F 200,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
G 200,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
H 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 40,3 kg
Share of renewable materials of total weight 74,17 %
Global warming potential (GWP-T) -39,462 kgCO2Äqv.
Energy use of Primary Energy 587,5 MJ
Share of renewable Primary Energy 21,5 %
∑ΔOI3 27,9
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 27,279 -66,740 -39,462 126,344 688,197 814,541 461,114 29,328 490,442 0,136 0,062 2.4916781E-6 0,026

Last update 02.08.2023/hfa.eco2soft