Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 46 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 58,7 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awrhho07a-09 (pdf, 250 KB)

Note

According to OIB-RL 2 (Austria) is for ventilated and insulated facades (from building class 2) an insulation material with minimum Euroclass D required.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens - ventilation 0,120 50 450 1,600 D
C 30,0 spruce wood cross battens 0,120 50 450 1,600 D
D wind barrier 1000
E 60,0 wood-fibre insulation board [045; 140] 0,045 2-5 140 2,100 E
F 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
G 160,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
H 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 45,4 kg
Share of renewable materials of total weight 80,27 %
Global warming potential (GWP-T) -50,057 kgCO2Äqv.
Energy use of Primary Energy 528,6 MJ
Share of renewable Primary Energy 24,1 %
∑ΔOI3 21,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 25,370 -75,427 -50,057 127,237 775,359 902,596 401,348 40,532 441,879 0,110 0,050 2.0965495E-6 0,023

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 52,3 kg
Biogenic carbon 76,5 kgCO2Äqv.
Energy use of Primary Energy 945,8 MJ
Share of renewable Primary Energy 38,6 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -73,555 0,107 0,022 6.54E-7 0,029 362,668 1049,663 1412,081 552,490 70,057 622,620
C1 - C4 99,789 0,002 0,000 7.56E-8 0,000 1,912 -1044,560 -1042,649 23,121 -42,595 -19,470
A1 - C4 26,596 0,110 0,023 7.37E-7 0,030 364,959 5,362 370,071 580,840 27,514 608,430

Last update 02.08.2023/hfa.eco2soft