Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,17 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -9)
Ln,w (Cl)
Vertical external battens and vertical battens for the dry lining screwed onto the ledger beams lead to an Rw(C;Ctr)=44(-1;-5) dB  
Assessed by MA39  
Mass per unit area m 75,8 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 65,0 spruce wood cross battens of battens offset 0,120 50 450 1,600 D
C 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
D 16,0 particleboard 0,130 50-100 700 1,700 D
E 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
F 160,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
G 12,0 particleboard 0,130 50-100 700 1,700 D
H vapour barrier sd≥ 10m 1000
I 40,0 spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
J 40,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
K 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
K 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 52,0
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -34,752 0,227 0,105 4,20e-6 0,017 188,661 702,844 891,506 781,891 43,404 825,294