Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,16 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 53 dB (-1; -6)
Ln,w (Cl)
Rating by MA39  
Mass per unit area m 80,8 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 24,0 spruce wood cross battens 0,120 50 450 1,600 D
C 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E 240,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
F 240,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
H 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 55,5 kg
Share of renewable materials of total weight 71,69 %
Global warming potential (GWP-T) -46,219 kgCO2Äqv.
Energy use of Primary Energy 660,3 MJ
Share of renewable Primary Energy 20,9 %
∑ΔOI3 30,9
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 33,865 -80,084 -46,219 137,930 815,316 953,245 522,354 28,891 551,246 0,152 0,065 2.7361385E-6 0,028

Last update 02.08.2023/hfa.eco2soft