Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,23 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-1; -6)
Ln,w (Cl)
Assessed by MA39  
Mass per unit area m 75,8 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 24,0 spruce wood cross battens 0,120 50 450 1,600 D
C 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
F 160,0 sheep wool [0,041; R=26] 0,041 1 30 1,720 E
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
H 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 25,9
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -46,956 0,133 0,054 2,59e-6 0,010 181,885 757,450 939,335 445,811 33,049 478,860

Last update 07.05.2020/hfa.plb