Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by MA39  
Thermal performance U 0,17 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-2; -7)
Ln,w (Cl)
Assessed by MA39  
Mass per unit area m 64,0 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 50,0 spruce wood cross battens 0,120 50 450 1,600 D
C 40,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E 200,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
F 200,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
H 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon 11,7
Calculated by IBO  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-59,4 0,263 688,3 1.297,3 0,037 0,012

Last update 30.08.2017/hfa.plb