Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-2; -7)
Ln,w (Cl)
Rating by MA39  
Mass per unit area m 66,4 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 50,0 spruce wood cross battens 0,120 50 450 1,600 D
C 40,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
F 160,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
H 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 48,4 kg
Share of renewable materials of total weight 72,79 %
Global warming potential (GWP-T) -39,507 kgCO2Äqv.
Energy use of Primary Energy 842,4 MJ
Share of renewable Primary Energy 17,0 %
∑ΔOI3 46,3
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 40,161 -79,667 -39,507 143,049 824,224 967,273 699,345 42,896 742,242 0,211 0,095 3.6530462E-6 0,034

Last update 02.08.2023/hfa.eco2soft