Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 52 dB (-2; -9)
Ln,w (Cl)
Vertical battens for the dry lining screwed onto the ledger beams lead to an Rw(C;Ctr)=49(-1;-7) dB  
Rating by MA39  
Mass per unit area m 80,6 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 24,0 planking spruce wood 0,120 50 450 1,600 D
D 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
E 160,0 sheep wool [0,041; R=26] 0,041 1 30 1,720 E
F 24,0 planking spruce wood 0,120 50 450 1,600 D
G vapour barrier sd≥ 7m 1000
H 40,0 spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I 40,0 sheep wool [0,041; R=26] 0,041 1 30 1,720 E
J 15,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 15,0 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 51,5 kg
Share of renewable materials of total weight 67,37 %
Global warming potential (GWP-T) -47,353 kgCO2Äqv.
Energy use of Primary Energy 635,6 MJ
Share of renewable Primary Energy 19,2 %
∑ΔOI3 28,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 37,620 -84,974 -47,353 122,245 895,394 1017,639 513,314 31,130 544,444 0,133 0,059 3.0185395E-6 0,028