Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, with dry lining, with rendering
Fire performance | REI from inside REI from outside |
60 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,13 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 54 dB (-3; -11) |
Ln,w (Cl) | ||
vertical battens for the dry lining screwed onto the structural timber lead to an Rw(C;Ctr)=52(-2;-8) dB
Rating by MA39
|
||
Mass per unit area | m | 70,6 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 60,0 | wood-fibre insulation board WF-PT [045; 180] | 0,045 | 5-7 | 180 | 2,100 | E |
C | 240,0 | construction timber (60/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
D | 240,0 | mineral wool [040; ≥16; <1000°C] | 0,040 | 1 | 16 | 1,030 | A1 |
E | 19,0 | particleboard | 0,130 | 50-100 | 700 | 1,700 | D |
F | vapour barrier sd≥ 2m | 1000 | |||||
G | 40,0 | spruce wood cross battens (a=400) or battens offset) | 0,120 | 50 | 450 | 1,600 | D |
H | 40,0 | mineral wool [040; ≥16; <1000°C] or air layer in type 02 | 0,040 | 1 | 16 | 1,030 | A1 |
I | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
I | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
ΔOI3 | 46,2 |
---|---|
Calculated by HFA |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase | GWP [kg CO2 Äqv.] | AP [kg SO2 Äqv.] | EP [kg PO4 Äqv.] | ODP [kg R11 Äqv.] | POCP [kg Ethen Äqv.] | PERE [MJ] | PERM [MJ] | PERT [MJ] | PENRE [MJ] | PENRM [MJ] | PENRT [MJ] |
A1 - A3 | -29,429 | 0,197 | 0,083 | 3,53e-6 | 0,012 | 95,213 | 677,236 | 772,450 | 683,863 | 59,223 | 743,087 |
Last update 25.01.2021/hfa.plb