Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, with dry lining, with rendering
Fire performance | REI from inside REI from outside |
60 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,19 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 52 dB (-2; -9) |
Ln,w (Cl) | ||
Vertical battens for the dry lining screwed onto the ledger beams lead to an Rw(C;Ctr)=50(-1;-7) dB
Rating by MA39
|
||
Mass per unit area | m | 70,0 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 60,0 | wood-fibre insulation board WF-PT [045; 180] | 0,045 | 5-7 | 180 | 2,100 | E |
C | 160,0 | construction timber (60/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
D | 160,0 | sheep wool [0,041; R=26] | 0,041 | 1 | 30 | 1,720 | E |
E | 19,0 | particleboard P4 | 0,130 | 50-100 | 700 | 1,700 | D |
F | vapour barrier sd≥ 2m | 1000 | |||||
G | 40,0 | spruce wood cross battens (a=400) or battens offset) | 0,120 | 50 | 450 | 1,600 | D |
H | 40,0 | sheep wool [0,041; R=26] or air layer in type 02 | 0,041 | 1 | 30 | 1,720 | E |
I | 15,0 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
I | 15,0 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
ΔOI3 | 35,3 |
---|---|
Calculated by HFA
|
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kg CO2 Äqv.] |
AP [kg SO2 Äqv.] |
EP [kg PO4 Äqv.] |
ODP [kg R11 Äqv.] |
POCP [kg Ethen Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -32,049 | 0,146 | 0,059 | 3,05e-6 | 0,011 | 85,076 | 725,765 | 810,841 | 572,782 | 61,728 | 634,510 |
Last update 25.01.2021/hfa.plb