Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside 60
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m  
Classified by HFA  
Thermal performance U 0,16 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 53 dB (-3; -11)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 88,4 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 10,0 plaster 1,000 10-35 2000 1,130 A1
B 25,0 Heraklith BM 0,090 2-5 370 2,000 B
C 16,0 particleboard P5 0,130 50-100 700 1,700 D
D 240,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 240,0 Heralan KP 0,040 1 28 1,030 A1
F vapour barrier sd≥ 9m 1000
G 50,0 Heraklith BM 0,090 2-5 370 2,000 B
H 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 40,9 kg
Share of renewable materials of total weight 48,27 %
Global warming potential (GWP-T) -11,247 kgCO2Äqv.
Energy use of Primary Energy 609,3 MJ
Share of renewable Primary Energy 11,0 %
∑ΔOI3 40,7
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 40,406 -51,653 -11,247 67,269 507,400 574,669 542,041 29,823 571,865 0,176 0,060 2.6391826E-6 0,052

Source: Knauf Insulation GmbH

Last update 02.08.2023/hfa.eco2soft