Building physical assessment

Fire performance REI from inside
REI from outside
30
90
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,13 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -10)
Ln,w (Cl)
Rating by TGM  
Mass per unit area m 78,3 kg/m2
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 80,0 WF-PT [042; 180] 0,042 3-7 180 2,100 E
C 22,0 planking spruce wood diagonal 0,120 50 450 1,600 D
D 200,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 200,0 Wood fibre insulation [039; 50] 0,039 1-2 50 2,100 E
F 22,0 planking spruce wood diagonal 0,120 50 450 1,600 D
G vapour barrier sd≥ 6m 1000
H 40,0 spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I 40,0 Wood fibre insulation [039; 50] 0,039 1-2 50 2,100 E
J 19,0 planking tongue and groove 0,120 50 450 1,600 D

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 28,7
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -76,734 0,169 0,067 2,80e-6 0,009 89,977 1129,692 1219,669 523,438 44,053 567,491