Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, with dry lining, with rendering
Fire performance |
REI
from inside
REI from outside |
30
90 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,11 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 52 dB (-3; -10) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 81,8 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 80,0 | WF-PT [042; 180] | 0,042 | 3-7 | 180 | 2,100 | E |
C | 22,0 | planking spruce wood diagonal | 0,120 | 50 | 450 | 1,600 | D |
D | 240,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | 240,0 | Wood fibre insulation [039; 50] | 0,039 | 1-2 | 50 | 2,100 | E |
F | 22,0 | planking spruce wood diagonal | 0,120 | 50 | 450 | 1,600 | D |
G | vapour barrier sd≥ 6m | 1000 | |||||
H | 40,0 | spruce wood cross battens (a=400) or battens offset) | 0,120 | 50 | 450 | 1,600 | D |
I | 40,0 | Wood fibre insulation [039; 50] | 0,039 | 1-2 | 50 | 2,100 | E |
J | 19,0 | planking tongue and groove | 0,120 | 50 | 450 | 1,600 | D |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 35,926 | -115,155 | -79,229 | 175,664 | 1188,305 | 1363,969 | 563,210 | 46,818 | 610,028 | 0,163 | 0,073 | 3.0083793E-6 | 0,035 |
Last update 02.08.2023/hfa.eco2soft