Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, with dry lining, with rendering
Fire performance | REI from inside REI from outside |
60 90 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,27 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 48 dB (-3; -10) |
Ln,w (Cl) | ||
If battens for the dry lining are carried out vertically and screwed to the structural timber the result is Rw=45dB
Rating by HFA
|
||
Mass per unit area | m | 51,5 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 5,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 120,0 | MW-PT [038; 95] | 0,038 | 95 | A1 | ||
C | 15,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
D | 140,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | 140,0 | mineral wool [038; ≥33; ≥1000°C] | 0,038 | 1 | 33 | 1,030 | A1 |
F | vapour barrier sd≥ 23m | 1000 | |||||
G | 40,0 | spruce wood cross battens 40/60mm (a=400) | 0,120 | 50 | 450 | 1,600 | D |
H | 40,0 | air layer | 1 | 1 | 1,008 | ||
I | 16,0 | Kronospan OSB-Firestop | 0,110 | 150-170 | 660 | 1,700 | B |
∑ΔOI3 | 56,4 |
---|---|
Calculated by HFA
|
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kgCO2Äqv.] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | 1,490 | 0,269 | 0,078 | 2,28e-6 | 0,100 | 79,128 | 433,742 | 512,870 | 583,012 | 26,841 | 609,853 |
Source: KRONOSPAN OSB, spol. s r. o.
Last update 02.08.2023/hfa.eco2soft