Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
90
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,13 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-4; -10)
Ln,w (Cl)
frequency range 50-3500: C50-3500 -11 dB; Ctr 50-3500 -23 dB  
Rating by HFA  
Mass per unit area m 68,2 kg/m2
 
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 100,0 0,040 1 100 1,030 A1
C 15,0 OSB 0,130 200 600 1,700 D
D 200,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 200,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
F 15,0 OSB 0,130 200 600 1,700 D
G vapour barrier sd≥ 14m
H 27,0 resilient channel a=625 vertical
I 27,0 mineral wool [035; 20; ≥1000°C] 0,035 1 20 1,030 A1
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 27,8 kg
Share of renewable materials of total weight 40,31 %
Global warming potential (GWP-T) 1,980 kgCO2Äqv.
Energy use of Primary Energy 784,9 MJ
Share of renewable Primary Energy 14,0 %
∑ΔOI3 62,1
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 47,979 -45,999 1,980 109,954 474,675 584,629 674,897 28,482 703,378 0,287 0,090 2.9042114E-6 0,102

Last update 02.08.2023/hfa.eco2soft