Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
90
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,13 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-4; -10)
Ln,w (Cl)
frequency range 50-3500: C50-3500 -11 dB; Ctr 50-3500 -23 dB  
Rating by HFA  
Mass per unit area m 71,5 kg/m2
 
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 100,0 0,040 1 100 1,030 A1
C 15,0 OSB 0,130 200 600 1,700 D
D 200,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 200,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
F 15,0 OSB 0,130 200 600 1,700 D
G vapour barrier sd≥ 14m
H 27,0 resilient channel a=625 vertical
I 27,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 37,6 kg
Share of renewable materials of total weight 51,54 %
Global warming potential (GWP-T) -16,572 kgCO2Äqv.
Energy use of Primary Energy 803,5 MJ
Share of renewable Primary Energy 15,5 %
∑ΔOI3 54,6
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 46,259 -62,831 -16,572 124,274 645,075 769,349 679,201 44,578 723,779 0,249 0,087 3.1660745E-6 0,076

Last update 02.08.2023/hfa.eco2soft