Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 42 dB (-1; -6)
Ln,w (Cl)
Rating by HFA  
Mass per unit area m 57,2 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [048; 180] 0,048 5-7 180 2,100 E
C 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
D 160,0 Cellulose fibre [039; 50] 0,039 3 50 2,110 E
E 8,0 Funderplan Biofaser (sealed with airtight tape) 0,180 185 1000 1,700 D
F 40,0 spruce wood battens vertical 0,120 50 450 1,600 D
G 40,0 air layer 1 1 1,008
H 15,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 15,0 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 34,6 kg
Share of renewable materials of total weight 55,36 %
Global warming potential (GWP-T) -26,808 kgCO2Äqv.
Energy use of Primary Energy 508,4 MJ
Share of renewable Primary Energy 13,4 %
∑ΔOI3 26,5
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 27,960 -54,768 -26,808 68,253 555,022 623,275 440,162 20,689 460,850 0,117 0,056 2.5757543E-6 0,016

Source: FunderMax GmbH

Last update 20.06.2024/hfa.plb