Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,17 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 43 dB (-1; -6)
Ln,w (Cl)
Rating by HFA  
Mass per unit area m 52,8 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [048; 180] 0,048 5-7 180 2,100 E
C 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
D 160,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
E 8,0 Funderplan Biofaser (sealed with airtight tape) 0,180 185 1000 1,700 D
F 40,0 spruce wood battens vertical 0,120 50 450 1,600 D
G 40,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
H 15,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 15,0 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 27,5 kg
Share of renewable materials of total weight 47,55 %
Global warming potential (GWP-T) -15,424 kgCO2Äqv.
Energy use of Primary Energy 601,1 MJ
Share of renewable Primary Energy 11,1 %
∑ΔOI3 34,5
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 31,526 -46,950 -15,424 66,714 473,925 540,640 534,344 20,689 555,032 0,139 0,067 3.0808976E-6 0,019

Source: FunderMax GmbH

Last update 20.06.2024/hfa.plb