Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
30
30
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 45 dB (-2; -6)
Ln,w (Cl)
Rating by MA39  
Mass per unit area m 47,7 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 4,0 plaster 1,000 10-35 2000 1,130 A1
B 50,0 Polystyrene EPS-F [0,040] 0,040 20-50 17 1,450 E
C 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
D 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
E 160,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
F vapour barrier sd≥ 13m 1000
G 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
G 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 8,4 kg
Share of renewable materials of total weight 18,82 %
Global warming potential (GWP-T) 17,394 kgCO2Äqv.
Energy use of Primary Energy 578,7 MJ
Share of renewable Primary Energy 7,8 %
∑ΔOI3 42,5
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 30,167 -12,773 17,394 45,157 125,783 170,940 533,496 36,048 569,544 0,155 0,067 3.0127561E-6 0,025

Last update 02.08.2023/hfa.eco2soft