Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, without dry lining, with rendering
Fire performance |
REI
from inside
REI from outside |
30
30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,20 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 44 dB (-2; -6) |
Ln,w (Cl) | ||
Rating by MA39
|
||
Mass per unit area | m | 48,4 kg/m2 |
Calculation based on gypsum plaster board type DF GF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 4,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 50,0 | Polystyrene EPS-F [0,040] | 0,040 | 20-50 | 17 | 1,450 | E |
C | 15,0 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
D | 160,0 | construction timber (60/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
E | 160,0 | cellulose fibre [040; E] | 0,040 | 1-2 | 55 | 2,000 | E |
F | vapour barrier sd≥ 13m | 1000 | |||||
G | 12,5 | gypsum fibre board or | 0,320 | 21 | 1000 | 1,100 | A2 |
G | 12,5 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 16,916 | -20,571 | -3,655 | 38,274 | 206,880 | 245,154 | 256,456 | 36,048 | 292,504 | 0,072 | 0,028 | 1.4650733E-6 | 0,016 |
Last update 02.08.2023/hfa.eco2soft