Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 50 dB (-2; -7)
Ln,w (Cl)
Rating by MA39  
Mass per unit area m 71,9 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
D 160,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
E 19,0 particleboard 0,130 50-100 700 1,700 D
F vapour barrier sd≥ 2m 1000
G 15,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
G 15,0 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 33,4 kg
Share of renewable materials of total weight 50,14 %
Global warming potential (GWP-T) -10,272 kgCO2Äqv.
Energy use of Primary Energy 877,0 MJ
Share of renewable Primary Energy 8,8 %
∑ΔOI3 56,4
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 45,523 -55,795 -10,272 77,365 565,788 643,153 799,672 57,446 857,118 0,221 0,100 4.1835336E-6 0,032

Last update 02.08.2023/hfa.eco2soft