external wall timber frame construction, not ventilated, without dry lining, with rendering
Fire performance | REI from inside REI from outside |
60 30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,24 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 43 dB (-2; -6) |
Ln,w (Cl) | ||
Rating by MA39
|
||
Mass per unit area | m | 48,8 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 4,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 50,0 | Polystyrene EPS-F [0,040] | 0,040 | 20-50 | 17 | 1,450 | E |
C | 16,0 | particleboard | 0,130 | 50-100 | 700 | 1,700 | D |
D | 120,0 | construction timber (60/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
E | 120,0 | mineral wool [040; ≥16; <1000°C] | 0,040 | 1 | 16 | 1,030 | A1 |
F | 16,0 | particleboard | 0,130 | 50-100 | 700 | 1,700 | D |
G | vapour barrier sd≥ 17m | 1000 | |||||
H | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
H | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
ΔOI3 | 27,2 |
---|---|
Calculated by HFA |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase | GWP [kg CO2 Äqv.] | AP [kg SO2 Äqv.] | EP [kg PO4 Äqv.] | ODP [kg R11 Äqv.] | POCP [kg Ethen Äqv.] | PERE [MJ] | PERM [MJ] | PERT [MJ] | PENRE [MJ] | PENRM [MJ] | PENRT [MJ] |
A1 - A3 | -18,156 | 0,102 | 0,041 | 1,79e-6 | 0,014 | 57,064 | 387,371 | 444,436 | 419,926 | 81,180 | 501,106 |
Last update 09.07.2020/hfa.plb