Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,20 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 50 dB (-3; -11)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 59,2 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
D 160,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
E 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 30,4 kg
Share of renewable materials of total weight 53,83 %
Global warming potential (GWP-T) -19,467 kgCO2Äqv.
Energy use of Primary Energy 609,5 MJ
Share of renewable Primary Energy 14,8 %
∑ΔOI3 34,7
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 31,339 -50,806 -19,467 89,910 518,303 608,212 519,549 34,613 554,162 0,146 0,065 2.9108085E-6 0,021

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 38,3 kg
Biogenic carbon 56,1 kgCO2Äqv.
Energy use of Primary Energy 871,8 MJ
Share of renewable Primary Energy 36,3 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -51,096 0,098 0,021 4.6E-7 0,026 314,201 808,607 1123,423 529,787 44,188 574,050
C1 - C4 76,980 0,003 0,000 4.14E-8 0,000 1,776 -803,401 -801,461 20,415 -42,595 -19,980
A1 - C4 26,923 0,103 0,022 5.08E-7 0,026 316,357 5,465 322,803 555,432 1,645 562,710

Last update 02.08.2023/hfa.eco2soft