Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,17 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -11)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 62,5 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 200,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
D 200,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
E 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 40,8 kg
Share of renewable materials of total weight 63,05 %
Global warming potential (GWP-T) -35,088 kgCO2Äqv.
Energy use of Primary Energy 633,3 MJ
Share of renewable Primary Energy 16,9 %
∑ΔOI3 32,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 33,363 -68,451 -35,088 106,766 698,008 804,774 526,540 48,617 575,157 0,140 0,062 2.8731846E-6 0,022

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 42,2 kg
Biogenic carbon 61,7 kgCO2Äqv.
Energy use of Primary Energy 990,7 MJ
Share of renewable Primary Energy 37,0 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -60,080 0,111 0,023 5.44E-7 0,029 364,185 932,666 1297,619 595,349 50,603 646,040
C1 - C4 88,759 0,003 0,001 4.64E-8 0,000 2,023 -927,452 -925,265 23,511 -49,010 -23,300
A1 - C4 29,719 0,116 0,025 5.97E-7 0,029 366,588 5,473 373,196 624,089 1,645 631,390

Last update 02.08.2023/hfa.eco2soft