Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,15 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 52 dB (-3; -11)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 62,6 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 240,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
D 240,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
E 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 34,1 kg
Share of renewable materials of total weight 53,18 %
Global warming potential (GWP-T) -19,687 kgCO2Äqv.
Energy use of Primary Energy 653,3 MJ
Share of renewable Primary Energy 15,4 %
∑ΔOI3 41,4
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 37,132 -56,819 -19,687 100,783 581,194 681,977 552,492 34,613 587,104 0,188 0,069 2.7544888E-6 0,052

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 34,2 kg
Biogenic carbon 50,3 kgCO2Äqv.
Energy use of Primary Energy 613,4 MJ
Share of renewable Primary Energy 29,1 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -24,113 0,118 0,019 7.74E-7 0,021 177,265 509,728 687,915 415,844 29,287 445,240
C1 - C4 49,270 0,003 0,003 5.11E-8 0,001 0,998 -503,219 -502,057 12,384 -17,052 -2,470
A1 - C4 28,605 0,124 0,023 8.34E-7 0,021 178,651 6,768 186,707 434,709 12,287 452,670

Last update 02.08.2023/hfa.eco2soft