Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
45
30
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m  
Classified by MA39  
Thermal performance U 0,22 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -9)
Ln,w (Cl)
Assessed by MA39  
Mass per unit area m 64,0 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [055; 200] 0,055 5-7 200 2,100 E
C 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
D 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
E 160,0 sheep wool [0,041; R=26] 0,041 1 30 1,720 E
F vapour barrier sd≥ 3m 1000
G 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
G 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon 6,2
Calculated by IBO  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-11,5 0,176 627,9 580,8 0,019 0,009

Last update 11.05.2017/hfa.plb