Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
90
maximum ceiling height = 3 m; maximum load Ed,fi = 50,0 kN/m  
Classified by HFA  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 52 dB (-2; -8)
Ln,w (Cl)
Rating by MA39  
Mass per unit area m 84,0 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 100,0 wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
D 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
E 160,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
F vapour barrier sd≥ 3m 1000
G 25,0 gypsum fibre board (2x12,5 mm) or 0,320 21 1000 1,100 A2
G 25,0 gypsum plaster board type DF (2x12,5 mm) 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 28,1 kg
Share of renewable materials of total weight 35,07 %
Global warming potential (GWP-T) -7,110 kgCO2Äqv.
Energy use of Primary Energy 760,8 MJ
Share of renewable Primary Energy 16,3 %
∑ΔOI3 43,9
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 39,744 -46,853 -7,110 124,120 420,990 545,111 636,655 32,878 669,534 0,171 0,074 3.7909258E-6 0,022

Last update 02.08.2023/hfa.eco2soft