Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, without dry lining, with rendering
Fire performance |
REI
from inside
REI from outside |
60
60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 50,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,22 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 51 dB (-2; -8) |
Ln,w (Cl) | ||
Rating by MA39
|
||
Mass per unit area | m | 74,0 kg/m2 |
Calculation based on gypsum plaster board type DF GF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 60,0 | wood-fibre insulation board WF-PT [045; 180] | 0,045 | 5-7 | 180 | 2,100 | E |
C | 15,0 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
D | 160,0 | construction timber (60/..; e=*) | 0,120 | 50 | 450 | 1,600 | D |
E | 160,0 | sheep wool [0,041; R=26] | 0,041 | 1 | 30 | 1,720 | E |
F | vapour barrier sd≥ 3m | 1000 | |||||
G | 25,0 | gypsum fibre board (2x12,5 mm) or | 0,320 | 21 | 1000 | 1,100 | A2 |
G | 25,0 | gypsum plaster board type DF (2x12,5 mm) | 0,250 | 10 | 800 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 36,688 | -42,154 | -5,466 | 107,892 | 391,698 | 499,589 | 505,405 | 22,592 | 527,997 | 0,123 | 0,052 | 3.1964248E-6 | 0,017 |
Last update 02.08.2023/hfa.eco2soft