Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
30
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by MA39  
Thermal performance U 0,20 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -9)
Ln,w (Cl)
Assessed by MA39  
Mass per unit area m 78,7 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [055; 200] 0,055 5-7 200 2,100 E
C 12,0 particleboard P5 0,130 50-100 700 1,700 D
D 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
E 160,0 cellulose fibre [0,040; R=55] 0,040 1-2 55 2,000 B
F 16,0 particleboard P4 0,130 50-100 700 1,700 D
G vapour barrier sd≥ 7m 1000
H 15,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 15,0 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 35,4
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -45,658 0,160 0,064 2,80e-6 0,012 104,695 747,392 852,088 576,649 73,410 650,060

Last update 07.05.2020/hfa.plb