Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -9)
Ln,w (Cl)
Rating by MA39  
Mass per unit area m 78,9 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 24,0 planking spruce wood 0,120 50 450 1,600 D
D 160,0 construction timber (60/..; e=*) 0,120 50 450 1,600 D
E 160,0 cellulose fibre [0,040; R=55] 0,040 1-2 55 2,000 B
F 24,0 planking spruce wood 0,120 50 450 1,600 D
G vapour barrier sd≥ 6m 1000
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 47,9 kg
Share of renewable materials of total weight 65,99 %
Global warming potential (GWP-T) -49,568 kgCO2Äqv.
Energy use of Primary Energy 515,2 MJ
Share of renewable Primary Energy 22,5 %
∑ΔOI3 22,1
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 25,809 -75,377 -49,568 116,032 777,076 893,108 399,208 21,724 420,932 0,123 0,053 2.3273989E-6 0,023

Last update 02.08.2023/hfa.eco2soft