Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,14 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 53 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 76,9 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [055; 200] 0,055 5-7 200 2,100 E
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D 240,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 240,0 mineral wool [040; 30; ≥1000°C] 0,040 1 30 1,030 A1
F vapour barrier sd≥ 3m 1000
G 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
H 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
H 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 33,0 kg
Share of renewable materials of total weight 42,30 %
Global warming potential (GWP-T) -14,047 kgCO2Äqv.
Energy use of Primary Energy 731,4 MJ
Share of renewable Primary Energy 18,1 %
∑ΔOI3 46,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 40,721 -54,768 -14,047 132,649 512,935 645,584 598,792 39,775 638,567 0,203 0,073 3.018642E-6 0,050

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 36,2 kg
Biogenic carbon 51,4 kgCO2Äqv.
Energy use of Primary Energy 676,2 MJ
Share of renewable Primary Energy 28,7 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -23,457 0,124 0,022 1.59E-6 0,017 192,612 530,332 724,165 452,928 46,856 499,890
C1 - C4 51,671 0,004 0,003 9.48E-8 0,001 0,726 -519,482 -518,591 15,976 -25,732 -7,550
A1 - C4 32,120 0,133 0,026 1.7E-6 0,018 194,204 11,368 207,162 481,977 21,240 508,910

Last update 02.08.2023/hfa.eco2soft