Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Proof: manufacturer-specific  
Thermal performance U 0,14 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 53 dB (-2; -8)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 81,2 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [055; 200] 0,055 5-7 200 2,100 E
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D 240,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 240,0 Cellulose fibre [040; 50] 0,040 1 50 2,000 E
F vapour barrier sd≥ 3m 1000
G 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
H 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
H 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 43,6 kg
Share of renewable materials of total weight 52,31 %
Global warming potential (GWP-T) -30,731 kgCO2Äqv.
Energy use of Primary Energy 680,5 MJ
Share of renewable Primary Energy 20,6 %
∑ΔOI3 36,3
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 35,788 -66,519 -30,731 140,065 634,581 774,646 540,414 39,775 580,189 0,166 0,068 3.0692277E-6 0,021

Last update 02.08.2023/hfa.eco2soft