Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by MA39  
Classified by HFA  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 52 dB (-2; -8)
Ln,w (Cl)
Assessed by MA39  
Mass per unit area m 78,0 kg/m2
Calculation based on gypsum plaster board type DF GF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [055; 200] 0,055 5-7 200 2,100 E
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 160,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
F vapour barrier sd≥ 3m 1000
G 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
H 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
H 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 29,4 kg
Share of renewable materials of total weight 39,09 %
Global warming potential (GWP-T) -2,639 kgCO2Äqv.
Energy use of Primary Energy 909,0 MJ
Share of renewable Primary Energy 14,5 %
∑ΔOI3 57,5
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 46,139 -48,778 -2,639 131,524 450,044 581,568 777,519 39,775 817,294 0,230 0,100 4.3817627E-6 0,028

Last update 02.08.2023/hfa.eco2soft