Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 23,4 kN/m  
Classified by HFA  
Thermal performance U 0,16 W/(m2K)
Diffusion adequate
Calculated by IBO  
Acoustic performance Rw (C;Ctr) 44 dB
Ln,w (Cl)
The acoustic insulation assessment is based on a length-related flow resistance of r≥5 kPa.s/m². If this value is lower for the insulation material used, the Rw value is reduced by 3dB.  
Rating by TGM  
Mass per unit area m 83,0 kg/m2
 
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 Plaster „weberpas topdry“ 0,450 10-35 1600 1,130 A2
B 140,0 WF-PT [042; 180] dynamic stiffness s'<15MN/m³. 0,042 3-7 180 2,100 E
C 15,0 Rigips Riduro 0,250 4-10 1000 1,050 A2
D 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 160,0 Cellulose fibre [040; 50] 0,040 1 50 2,000 E
F vapour barrier sd≥ 6m 1000
G 15,0 Rigips Riduro 0,250 4-10 1000 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 15,8 kg
Share of renewable materials of total weight 20,44 %
Global warming potential (GWP-T) 33,590 kgCO2Äqv.
Energy use of Primary Energy 806,5 MJ
Share of renewable Primary Energy 7,5 %
∑ΔOI3 74,5
Calculated by IBO  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 54,782 -21,192 33,590 60,085 223,860 283,945 746,373 29,600 775,973 0,323 0,093 3.4746836E-6 0,112

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/hfa.eco2soft