flat roof solid wood construction, not ventilated, with dry lining, suspended
| Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
|---|---|---|---|---|---|---|---|
| λ | μ min – max | ρ | c | ||||
| A | 80,0 | wooden grating/wooden terrace | 0,130 | 50 | 500 | 1,600 | D |
| B | sealing sheet sd≥ 100m | ||||||
| C | separation nonwoven | ||||||
| D | 30,0 | impact sound absorbing subflooring MW-T | 0,036 | 1 | 130 | 1,030 | A1 |
| E | - variable insulation material (2*100) | ||||||
| F | sealing sheet bitumen | ||||||
| G | 140,0 | solid glued wood ≥ 140,0; at least 5-layers, top layer at least 26 mm | 0,130 | 50 | 500 | 1,600 | D |
| H | 70,0 | acoustic hanger (suspension); e=415; | |||||
| I | - variable building material | ||||||
| J | 12,5 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
| J | 12,5 | gypsum fibre board or | 0,320 | 21 | 1000 | 1,100 | A2 |
| Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
Last update 02.08.2023/nu.ge